Voltage: |
3 V |
Application: |
Optical Equipment, Medical Device |
No Load Speed: |
9 Rpm |
No Load Current: |
95 MA |
Rated Load Speed: |
8 Rpm |
Rated Load Current: |
135 MA |
Rated Torque: |
550 Gf.cm |
Gear Ratio: |
1296:1 |
Medical Facility Hygienic Design Planetary Gear Box 550gf Cm Troque 12mm
Specifications
Technical Parameter
|
product
|
12mm medical facility hygienic design planetary gear box 550gf cm Troque
|
motor
|
DC brush motor
|
torque
|
550 gf.cm or customized
|
rated speed
|
8 rpm |
reduction ratio |
1296 or customized
|
noise level
|
less than 40dB
|
life time
|
500 hours
|
working temperature
|
-40 to 95℃
|
Certification
|
ROHS/ISO9001/ISO14001/SGS/TS16949
|
Suitable for
|
Optical equipment, Medical device, Electronic switch(lock), Toy, Robot, Electric toothbrush, E-cigarette, and etc.
|
OSD Language
|
English, French, German, Italian, Russian, Spanish, Portuguese, Dutch, Greek, Japan, Korean
|
The basic specifications for reference only, specifications can be customized.
|
Description
Model |
Typical Application Parameters |
Max Rated Torque of Gear Box |
Max Instant Torque of Gear Box |
Gear Ratio |
Gear Box Length |
Rated |
At No Load |
At Rated Load |
Overall Length |
Voltage |
Speed |
Current |
Speed |
Current |
Torque |
VDC |
rpm |
mA(MAX) |
rpm |
mA(MAX) |
gf.cm |
mN.m |
mm |
gf.cm |
gf.cm |
mm |
DA012012-96 |
3.0 |
116 |
90 |
104 |
135 |
81 |
7.9 |
29.5 |
350 |
1000 |
96 |
14.5 |
DA012012-144 |
3.0 |
77 |
90 |
69 |
135 |
122 |
11.9 |
350 |
1000 |
144 |
DA012012-216 |
3.0 |
52 |
90 |
46 |
135 |
182 |
17.9 |
350 |
1000 |
216 |
DA012012-256 |
3.0 |
44 |
95 |
39 |
135 |
162 |
15.9 |
33.3 |
550 |
1100 |
256 |
18.3 |
DA012012-384 |
3.0 |
29 |
95 |
26 |
135 |
243 |
23.8 |
550 |
1100 |
384 |
DA012012-576 |
3.0 |
19 |
95 |
17 |
135 |
365 |
35.7 |
550 |
1100 |
576 |
DA012012-864 |
3.0 |
13 |
95 |
12 |
135 |
547 |
53.6 |
550 |
1100 |
864 |
DA012012-1296 |
3.0 |
9 |
95 |
8 |
135 |
550 |
53.9 |
550 |
1100 |
1296 |
above specifications just for reference and customizable according to requirements
Quality Control
* Life Test : being continuously working for required period of time, then stop, then repeat
* Noise Test : being put at the distance of 1m (or other requirements) to the test equipments to test the noise
* Water-proof Test : being put 10mm under the water working for 2 weeks and 100m under the water working for 12 hours
* Salt Spray Test : salt spray can test the products’ resistance to corrosion
* Impact Test : two objects striking each other at high relative speeds
* Storage Test : being stored under normal temperature for 1 or 2 years to test stability
* Environmental Related Substance